The Quick Reference Card provides a quick
overview of your spa’s main functions and
the operations accessible with your digital
control pad.
Spa Functions
Troubleshooting
98
k
ey 1 Light key Up key Down Key
S
mart winter mode
indicator
J
et Pump
indicator
L
ight
indicator
F
ilter
indicator
H
eat
indicator
S
et Point
indicator
Key 1
Press Key 1 key once to turn the optional jet
pump on. Press it again time to turn jets off.
A built-in timer automatically turns pump
off after 20 minutes, unless pump has been
manually deactivated first.
The “Pump 1” indicator lights up
when Pump 1 is on.
Light Key
Press Light key to turn light on. Press a sec-
ond time to turn light off. A built-in timer
automatically turns light off after 2 hours,
unless it has been manually deactivated first.
The “Light indicator lights up when
light is on.
Up/Down Keys
Use Up or Down key to set desired water
temperature. The temperature setting will be
displayed for 5 seconds to confirm your
new selection.
The “Set Point icon indicates that the
display shows the desired temperature,
NOT the current water temperature!
Off Mode
This mode allows you to stop all outputs for
30 minutes to perform a quick spa mainte-
nance.
Press and hold Key 1 key for 5 secs to activate
the Off mode. Quick press Key 1 key to
reactivate the system before the expiration
of the 30-minute delay.
While the Off mode is engaged, the display
will toggle between OFF and the water
temperature.
98
98
98
HL
AOH
FLO
OH
UPL
OFF
Hr
An internal hardware error has been
detected in in.xe. Contact Customer
Service.
HL
The system has shut the heater down
because the temperature at the heater
has reached 119°F (48°C). Do not
enter the water! Remove the spa cover
and allow the water to cool down,
then shut power off and power your
spa up again to reset the system.
AOH
Temperature inside the spa skirt is too
high, causing the internal temperature
in the in.xe to increase above normal
limits. Open skirt and wait until error
clears.
FLO
The system does not detect any water
flow while the primary pump is run-
ning. Check and open water valves.
Check for water level. Clean filter. If
the problem persists, call Customer
Service.
Prr
A problem is detected with the tem-
perature probe.Call Customer Service.
OH
The water temperature in the spa has
reached 108°F (42°C). Do not enter
the water! Remove the spa cover and
allow the water to cool down to a
lower temperature. Call Customer
Service if problem persists.
UPL
No low level configuration software has
been installed into the system. Call
Customer Service.
Water temperature Smart Winter Mode
In a heating cycle, the system first generates water flow through
the heater housing and the plumbing, in order to ensure accurate
water temperature readings as well as avoiding heater activation
in dry conditions.
After verifying pump activation and taking a water temperature
reading if required, the system automatically turns the heater on
to reach and maintain water temperature at Set Point.
The “Heater indicator lights up when the heater is on.
It flashes when there is a request for more heat but the
heater has not yet started.
Our Smart Winter Mode protects your system from the cold by
turning pumps on several times a day to prevent water from
freezing in pipes.
The “Smart Winter Mode indicator lights up when the Smart
Winter Mode is on.
Purge Cycles
The system is programmed to automatically turn on the option-
al jet pump 4 times daily, for 60 seconds, in order to purge the
plumbing lines and keep plumbing lines filtered clean.