Endless Pools Pools Spécifications Page 15

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 14
L
ow-Voltage - (LV) connectors:
Output Typical Device
C . . . . . . . . . . . . . . . . . . . . .Main keypad
CO . . . . . . . . . . . . . . . . . . . .Comm.connector (in.stik)
L
1 . . . . . . . . . . . . . . . . . . . . .Light
Typical Settings
Set Point : 59°F to 104°F / Factory set at 84°F
F
ilter Cycle Duration: 0 to 24 hrs / Factory set at 24 hrs
Jet Pump Run Time: 1 to 255 min. / Factory set at 30 min.
Light Timeout: 1 to 255 min. / Factory set at 120 min.
Max Set Point: 59°F to 104°F / Factory set at 104°F
Purge Cycle Frequency: 1 to 4 times a day / Factory set at 4
Keypad doesnt seem to work
If a keypad doesn’t seem to work:
• Verify keypad connections.
Replace keypad if problem is corrected.
Replace in.xe if problem is not corrected.
in.xe UL/CSA electrical specifications:
Input rating: 120/240 VAC
(2-phase required, with neutral) 48 A maximum, 60Hz. Software lim-
ited to 24A. Install on a 30A GFCI circuit.
Output ratings:
Output Voltage Current Typical Device
Out 1 120/240V 17FLA Pump 1
Out 3 120/240V 0.8 A Circulation Pump(CP)/Blower
Out 4 120/240V 1 A Ozone Generator
Out 5 120/240V 5 A Audio/Video device
L1 Light, 12VAC, 0.1 A
CO Communications port *
C1 Top side controller *
*CO: Comm.connector (in.stik).
heat.wav ratings:
Voltage: 120/240VAC
Current: 17A resistive (4 kW heater at 240V)
Frequency: 50 / 60 Hz
heat.wav heater flow rate:
Minimum of 18 GPM is required
Important:
All low voltage accessories use + 5Vdc and/or + 12 Vdc.
• All low voltage accessories combined: 150 mA max, on + 12 Vdc.
General specifications:
Environmental:
O
perating temperature: -20°C (-4°F) to 60°C (140°F)
Storage temperature: -25°C (-13°F) to 85°C (185°F)
Humidity: up to 85% RH, non condensing
IPx5 level of waterproofing is conditional on 3 items:
• Both front covers (heater and input wiring) are closed and
s
crewed shut.
• A waterproof strain-relief/bushing is used for the cable entry
into the pack.
• Any unused in.link connections (HC, LC, or low voltage) is
plugged with the appropriate blank plug.
Mechanical:
Weight: 4.76 kg (10.5 lbs)
Dimensions (W x H x D):
Chassis: 441.5mm x 298.5mm x 129mm (17.38" x 11.75" x 5.1")
UL/CSA Standards:
UL 1563 Fifth Ed.
File: E182156
CSA No. 22.2 - 218.1-M89.
TUV Standards:
EN/IEC 60335 - 2 - 60
EN55014-1
EN55014-2
EN61000-3-2
EN61000-3-3
The in.xe is lab tested to IPx5 enclosure protection levels.
18. E14 Series Sealless Centrifugal
Canned Motor Pumps
Laing centrifugal pumps are designed for circulation and transfer of a
variety of fluids compatible with their materials of construction limited
to maximum fluid temperatures and maximum line pressures as indi-
cated below. Unique leakproof integrated motor/pump design elimi-
nates the need for conventional mechanical seals or other shaft sealing
devices. They are self lubricating and require no external lubrication.
Unpacking
When unpacking the unit inspect carefully for any damage that may have
occurred during transit. Check for loose, damaged, or missing parts (see
pump exploded view and replacement parts list). Do not attempt to
assemble or operate pump if any parts are missing or damaged.
15